History Data
History Data
Gauge Calibration Control Record (group#336)
Approved
Checked
Gauge no. IP-ID-RG-9.0 A
Gauge control name Go-No-Go Gauge ID-NUT
Approved
Checked
Tool standard name Accuracy Resolution Temp. control
MICRO METER / C-23 ±1 um. 0.001 mm. 18 -23º C
Calib. date Next Calib. Cycle Calibrated by
2026-11-01 01:17 PM 2027-05-01 6 mth NUENGRUTHAI
Point
A
Measurement sub group
1st 2nd 3rd
Spec. 8.900 8.900 8.900
±Tol. 0.010 / 0.000 0.010 / 0.000 0.010 / 0.000
Actual 8.909 8.909 8.909
Diff.
0.009
0.009
0.009
Judge
Ok
Ok
Ok
Point
B
Measurement sub group
1st 2nd 3rd
Spec. 9.100 9.100 9.100
±Tol. 0.000 / -0.010 0.000 / -0.010 0.000 / -0.010
Actual 9.092 9.092 9.092
Diff.
-0.008
-0.008
-0.008
Judge
Ok
Ok
Ok
Factory Data
  • Wanna join ?
  • . .
Small Tools
UICT Factory Enterprise Edition