History Data
History Data
Gauge Calibration Control Record (group#258)
Approved
Checked
Gauge no. IP-ID-RG-7.6 A
Gauge control name Go-No-Go Gauge ID-NUT
Approved
Checked
Tool standard name Accuracy Resolution Temp. control
MICRO METER / C-23 ±1 um. 0.001 mm. 18 -23º C
Calib. date Next Calib. Cycle Calibrated by
2026-11-01 01:18 PM 2027-05-01 6 mth NUENGRUTHAI
Point
A
Measurement sub group
1st 2nd 3rd
Spec. 7.600 7.600 7.600
±Tol. 0.010 / 0.000 0.010 / 0.000 0.010 / 0.000
Actual 7.605 7.607 7.604
Diff.
0.005
0.007
0.004
Judge
Ok
Ok
Ok
Point
B
Measurement sub group
1st 2nd 3rd
Spec. 7.820 7.820 7.820
±Tol. 0.000 / -0.010 0.000 / -0.010 0.000 / -0.010
Actual 7.818 7.819 7.818
Diff.
-0.002
-0.001
-0.002
Judge
Ok
Ok
Ok
Factory Data