History Data
History Data
Gauge Calibration Control Record (group#7be)
Approved
Checked
Gauge no. FMGPH27UIC AC
Gauge control name OD-HEAD-INSPECTION TYPE PH-27
Approved
Checked
Tool standard name Accuracy Resolution Temp. control
IMAGE / IM-02
⚬ Wide-field: ±2 um.
⚬ High-precision: ±5 um.
±2 um. 18 - 23º C
Calib. date Next Calib. Cycle Calibrated by
2026-10-02 01:18 PM 2027-04-02 6 mth NUENGRUTHAI
Point
1
Measurement sub group
1st 2nd 3rd
Spec. 8.440 8.440 8.440
±Tol. 0.020 / 0.000 0.020 / 0.000 0.020 / 0.000
Actual 8.451 8.451 8.451
Diff.
0.011
0.011
0.011
Judge
Ok
Ok
Ok
Point
2
Measurement sub group
1st 2nd 3rd
Spec. 8.760 8.760 8.760
±Tol. 0.000 / -0.020 0.000 / -0.020 0.000 / -0.020
Actual 8.748 8.748 8.748
Diff.
-0.012
-0.012
-0.012
Judge
Ok
Ok
Ok